# ICS Advisory (ICSA-19-253-03)
## Siemens Industrial Products (Update J)
Original release date: October 13, 2020
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-253-03)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-253-03)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-253-03)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 7.5**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** Siemens
* **Equipment:** Industrial Products
* **Vulnerabilities:** Excessive Data Query Operations in a Large Data Table, Integer Overflow or Wraparound, Uncontrolled Resource Consumption
## 2\. UPDATE INFORMATION
This updated advisory is a follow-up to the updated advisory titled
ICSA-19-253-03 Siemens Industrial Products (Update I) that was published
September 8, 2020, to the ICS webpage on us-cert.gov.
## 3\. RISK EVALUATION
Successful exploitation of these vulnerabilities could cause denial-of-service
condition.
## 4\. TECHNICAL DETAILS
### 4.1 AFFECTED PRODUCTS
Siemens reports the vulnerabilities affect the following industrial products:
* CloudConnect 712: All versions prior to 1.1.5
* ROX II: All versions prior to 2.13.3 (Only vulnerable to CVE-2019-11479)
* RUGGEDCOM APE 1404 Linux: All versions prior to Debian 9 Linux Image 2019-12-13 (only affected by CVE-2019-11479)
* RUGGEDCOM RM1224: All versions prior to 6.2
* RUGGEDCOM RX 1400 VPE Debian Linux: All versions prior to Debian 9 Linux Image 2019-12-13 (only affected by CVE-2019-11479)
* RUGGEDCOM RX 1400 VPE Linux CloudConnect: All versions prior to Debian 9 Linux Image 2019-12-13 13 (only affected by CVE-2019-11479)
* SCALANCE M800 / S615: All versions prior to 6.2
* SCALANCE M875: All versions
* SCALANCE SC-600: All versions prior to 2.0.1
* SCALANCE W1700: All versions prior to 2.0
* SCALANCE W-700 (IEEE 802.11n): All versions prior to 6.4
* SCALANCE WLC711: All versions
* SCALANCE WLC712: All versions
* SIMATIC CM 1542-1: All versions
* SIMATIC ITC1500: All versions
* SIMATIC ITC1500 PRO: All versions
* SIMATIC ITC1900: All versions
* SIMATIC ITC1900 PRO: All versions
* SIMATIC ITC2200: All versions
* SIMATIC ITC2200 PRO: All versions
**\--------- Begin Update J Part 1 of 2 ---------**
* SCALANCE W1750D: All versions prior to 8.6.0
* SIMATIC MV500: All versions prior to 2.1
**\--------- End Update J Part 1 of 2 ---------**
* SIMATIC NET CP 1242-7: All versions prior to 3.2
* SIMATIC NET CP 1243-1 (incl. SIPLUS NET variants): All versions prior to 3.2
* SIMATIC NET CP 1243-7 LTE EU: All versions prior to 3.2
* SIMATIC NET CP 1243-7 LTE US: All versions prior to 3.2
* SIMATIC NET CP 1243-8 IRC: All versions prior to 3.2
* SIMATIC NET CP 1542SP-1: All versions prior to 2.1
* SIMATIC NET CP 1542SP-1 IRC (incl. SIPLUS NET variants): All versions prior to 2.1
* SIMATIC NET CP 1543-1 (incl. SIPLUS NET variants): All versions prior to 2.2
* SIMATIC NET CP 1543SP-1 (incl. SIPLUS NET variants): All versions prior to 2.1
* SIMATIC NET CP 1623: All versions: All versions (only affected by CVE-2019-8460)
* SIMATIC NET CP 1628: All versions: All versions (only affected by CVE-2019-8460)
* SIMATIC NET CP 343-1 Advanced (incl. SIPLUS NET variants): All versions (only affected by CVE-2019-8460)
* SIMATIC NET CP 442-1 RNA: All versions (only affected by CVE-2019-8460)
* SIMATIC NET CP 443-1 (incl. SIPLUS NET variants): All versions (only affected by CVE-2019-8460)
* SIMATIC NET CP 443-1 Advanced (incl. SIPLUS NET variants): All versions (only affected by CVE-2019-8460)
* SIMATIC NET CP 443-1 OPC UA: All versions (only affected by CVE-2019-8460)
* SIMATIC NET CP 443-1 RNA: All versions (only affected by CVE-2019-8460)
* SIMATIC RF185C: All versions prior to 1.3
* SIMATIC RF186C: All versions prior to 1.3
* SIMATIC RF186CI: All versions prior to 1.3
* SIMATIC RF188C: All versions prior to 1.3
* SIMATIC RF188CI: All versions prior to 1.3
* SIMATIC RF600R: All versions
* SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (incl. SIPLUS variant): All versions
* SIMATIC Teleserver Adapter IE Advanced: All versions
* SIMATIC Teleserver Adapter IE Basic: All versions
* SINEMA Remote Connect Server: All versions prior to 2.1
* SINUMERIK 808D: All versions prior to 4.92
* SINUMERIK 828D: All versions prior to 4.8 SP5
* SINUMERIK 840D sl: All versions prior to 4.8 SP5
* TIM 1531 IRC (incl. SIPLUS NET variants): All versions prior to 2.1
### 4.2 VULNERABILITY OVERVIEW
#### 4.2.1 [EXCESSIVE DATA QUERY OPERATIONS IN A LARGE DATA TABLE
CWE-1049](https://cwe.mitre.org/data/definitions/1049.html)
The kernel can be forced to make very expensive calls for every incoming TCP
Selective Acknowledgement (SACK) packet which can lead to a denial-of-service
condition.
[CVE-2019-8460](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8460)
has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)).
#### 4.2.2 [INTEGER OVERFLOW OR WRAPAROUND
CWE-190](https://cwe.mitre.org/data/definitions/190.html)
The kernel is affected by an integer overflow when handling TCP Selective
Acknowledgements, which could allow a remote attacker to cause a denial-of-
service condition.
[CVE-2019-11477](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-11477)
has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)).
#### 4.2.3 [UNCONTROLLED RESOURCE CONSUMPTION ('RESOURCE EXHAUSTION')
CWE-400](https://cwe.mitre.org/data/definitions/400.html)
A remote attacker sending specially crafted TCP Selective Acknowledgment
(SACK) sequences may cause a denial-of-service condition.
[CVE-2019-11478](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-11478)
has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L)).
#### 4.2.4 [UNCONTROLLED RESOURCE CONSUMPTION ('RESOURCE EXHAUSTION')
CWE-400](https://cwe.mitre.org/data/definitions/400.html)
An attacker may exploit a vulnerability in the TCP retransmission queue
implementation kernel when handling TCP Selective Acknowledgements (SACK) to
cause a denial-of-service condition.
[CVE-2019-11479](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-11479)
has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L)).
### 4.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems
* **COUNTRIES/AREAS DEPLOYED:** Worldwide
* **COMPANY HEADQUARTERS LOCATION:** Germany
### 4.4 RESEARCHER
Siemens reported theses vulnerabilities to CISA.
## 5\. MITIGATIONSSiemens recommends users follow the specific workarounds and
mitigations below. Siemens has also released fixes for the following products:
* CloudConnect 712: [Update to v1.1.5](https://support.industry.siemens.com/cs/ww/en/view/109769636)
* ROX II: [Update to v2.13.3](https://support.industry.siemens.com/cs/document/109778537) (Only vulnerable to CVE-2019-11479)
* RUGGEDCOM APE 1404 Linux: [Apply the latest available Debian patches](https://support.industry.siemens.com/cs/document/109773487)
* RUGGEDCOM RM1224: [Update to v6.2 or later](https://support.industry.siemens.com/cs/document/109778305)
* RUGGEDCOM RX1400 VPE Debian Linux: [Apply the latest available Debian patches in the VPE](https://support.industry.siemens.com/cs/document/109773485)
* RUGGEDCOM RX1400 VPE Linux CloudConnect: [Apply the latest available Debian patches in the VPE or apply the latest CloudConnect VPE Linux image](https://support.industry.siemens.com/cs/document/109773486)
* SCALANCE M800: [Update to v6.2 or later](https://support.industry.siemens.com/cs/document/109778305)
* SCALANCE S615: [Update to v6.2 or later](https://support.industry.siemens.com/cs/document/109778305)
* SCALANCE M875: Upgrade hardware to SCALANCE M876-4 or RUGGEDCOM RM1224 and apply patches when available
* SCALANCE SC-600: [Update to v2.0.1](https://support.industry.siemens.com/cs/ww/en/view/109769665)
* SCALANCE W1700: [Update to v2.0 or later](https://support.industry.siemens.com/cs/document/109773734)
* SCALANCE W700 (IEEE 802.11n): [Update to v6.4 or newer](https://support.industry.siemens.com/cs/ww/en/view/109773308)
**\--------- Begin Update J Part 2 of 2 ---------**
* SCALANCE W1750D: [Update to v8.6.0 or later](https://support.industry.siemens.com/cs/ww/en/view/109778052)
* SIMATIC MV500: [Update to v2.1 or later](https://support.industry.siemens.com/cs/ww/en/view/109781769)
**\--------- End Update J Part 2 of 2 ---------**
* SIMATIC NET CP 1242-7: Update to v3.2 or later
* SIMATIC NET CP 1243-1 (incl. SIPLUS NET variants): [Update to v3.2 or later](https://support.industry.siemens.com/cs/document/109775640)
* SIMATIC NET CP 1243-7 LTE EU: [Update to v3.2 or later](https://support.industry.siemens.com/cs/document/109775640)
* SIMATIC NET CP 1243-7 LTE US: [Update to v3.2 or later](https://support.industry.siemens.com/cs/document/109775640)
* SIMATIC NET CP 1243-8 IRC: [Update to v3.2 or later](https://support.industry.siemens.com/cs/document/109775640)
* SIMATIC NET CP 1542SP-1: [Update to v2.1 or later](https://support.industry.siemens.com/cs/document/109774207/)
* SIMATIC NET CP 1542SP-1 IRC (incl. SIPLUS NET variants): [Update to v2.1 or later](https://support.industry.siemens.com/cs/document/109774207/)
* SIMATIC NET CP 1543-1 (incl. SIPLUS NET variants): [Update to v2.2 or later](https://support.industry.siemens.com/cs/document/109775642)
* SIMATIC NET CP 1543SP-1 (incl. SIPLUS NET variants): [Update to v2.1 or later](https://support.industry.siemens.com/cs/document/109774207/)
* SIMATIC RF185C: [Update to v1.3 or later](https://support.industry.siemens.com/cs/ww/en/view/109781665)
* SIMATIC RF186C: [Update to v1.3 or later](https://support.industry.siemens.com/cs/ww/en/view/109781665)
* SIMATIC RF186CI: [Update to v1.3 or later](https://support.industry.siemens.com/cs/ww/en/view/109781665)
* SIMATIC RF188C: [Update to v1.3 or later](https://support.industry.siemens.com/cs/ww/en/view/109781665)
* SIMATIC RF188CI: [Update to v1.3 or later](https://support.industry.siemens.com/cs/ww/en/view/109781665)
* SINEMA Remote Connect Server: [Update to v2.1](https://support.industry.siemens.com/cs/ww/en/view/109777247)
* SINUMERIK 808D: Update to v4.92. The update can be obtained from a Siemens representative or via Siemens customer service.
* SINUMERIK 828D/840D sl: Update to v4.8 SP5. The update can be obtained from a Siemens representative or via Siemens customer service.
* TIM 1531 IRC (incl. SIPLUS NET variants): [Update to v2.1 or later](https://support.industry.siemens.com/cs/document/109774204)
Siemens has identified the following specific workarounds and mitigations that
customers can apply to reduce the risk:
* Restrict network access to affected devices
* Apply defense-in-depth
* For SIMATIC Teleservice Adapters (IE Basic, IE Advanced): migrate to a successor product within the SCALANCE M-800 family. For details refer to the [notice of discontinuation](https://support.industry.siemens.com/cs/ww/en/view/109781070).
As a general security measure, Siemens strongly recommends users protect
network access to devices with appropriate mechanisms. In order to operate the
devices in a protected IT environment, Siemens recommends users configure the
environment according to Siemens' [operational guidelines for industrial
security](https://www.siemens.com/cert/operational-guidelines-industrial-
security), and follow the recommendations in the product manuals. Additional
information on industrial security by Siemens can be found at:
<https://www.siemens.com/industrialsecurity>
For more information, please see Siemens Security Advisory
[SSA-462066](http://www.siemens.com/cert/advisories)
CISA recommends users take defensive measures to minimize the risk of
exploitation of these vulnerabilities. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls and isolate them from the business network.
* When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.