# ICS Advisory (ICSA-19-295-01)
## Schneider Electric ProClima
Original release date: October 22, 2019
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-295-01)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-295-01)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2Ficsa-19-295-01)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 9.8**
* **ATTENTION:** Exploitable remotely/low skill level to exploit
* **Vendor:** Schneider Electric
* **Equipment:** Proclima
* **Vulnerabilities:** Code Injection, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Search Path Element
## 2\. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an
unauthenticated, remote attacker to execute arbitrary code on the targeted
system.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
Schneider Electric reports these vulnerabilities affect the following ProClima
building and automation control products:
* ProClima, all versions prior to 8.0.0
### 3.2 VULNERABILITY OVERVIEW
#### 3.2.1 [IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION')
CWE-94](https://cwe.mitre.org/data/definitions/94.html)
A code injection vulnerability could allow an unauthenticated, remote attacker
to execute arbitrary code on the targeted system.
[CVE-2019-6823](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6823)
has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H)).
#### 3.2.2 [IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY
BUFFER CWE-119](https://cwe.mitre.org/data/definitions/119.html)
A buffer error vulnerability could allow an unauthenticated, remote attacker
to execute arbitrary code on the targeted system.
[CVE-2019-6824](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6824)
has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H)).
#### 3.2.3 [UNCONTROLLED SEARCH PATH ELEMENT
CWE-427](https://cwe.mitre.org/data/definitions/427.html)
An uncontrolled search path element vulnerability could allow a malicious DLL
file with the same name of any resident DLLs inside the software installation
to execute arbitrary code.
[CVE-2019-6825](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6825)
has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been
calculated; the CVSS vector string is
([AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H)).
### 3.3 BACKGROUND
* **CRITICAL INFRASTRUCTURE SECTORS:** Commercial Facilities, Critical Manufacturing, and Energy
* **COUNTRIES/AREAS DEPLOYED:** United States, Europe, and Asia
* **COMPANY HEADQUARTERS LOCATION:** France
### 3.4 RESEARCHER
Haojun Hou reported a vulnerability to CISA. Kushal Arvind Shah of
Fortinet,Yongjun Liu of NSFOCUS security team, and Telus reported
vulnerabilities to Schneider Electric.
## 4\. MITIGATIONS
Schneider Electric has released Version 8.0.0 of ProClima and recommends users
upgrade to this version or newer. Users may find the new version at the
following location on the Schneider Electric website:
[https://www.schneider-electric.com/en/product-range-
download/2560-proclima/#tabs-top ](https://www.schneider-
electric.com/en/product-range-download/2560-proclima/#tabs-top )
For more information on these vulnerabilities and the associated upgrade,
please see Schneider Electric's SEVD-2019-162-01:
<https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/>
Schneider Electric recommends the following best cybersecurity practices for
industry:
* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
* Physical controls should be in place so no unauthorized person has access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.
* All controllers should reside in locked cabinets and never be left in "Program" mode.
* All programming software should be kept in locked cabinets and should never be connected to any network other than the network for devices intended.
* All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.
* Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.
* Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.
* When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
For further information related to cybersecurity in Schneider Electric's
products, please visit the company's cybersecurity webpage:
<http://www2.schneider-
electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page>
If you require additional support, Schneider Electric Industrial Cybersecurity
Services team is available to help. Please visit:
<https://www.schneider-electric.com/en/work/services/field-
services/industrial-automation/industrial-cybersecurity/industrial-
cybersecurity.jsp>
CISA reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
CISA also recommends users take the following measures to protect themselves
from social engineering attacks:
* Do not click web links or open unsolicited attachments in email messages.
* Refer to [Recognizing and Avoiding Email Scams](https://www.us-cert.gov/sites/default/files/publications/emailscams_0905.pdf) for more information on avoiding email scams.
* Refer to [Avoiding Social Engineering and Phishing Attacks](https://www.us-cert.gov/ncas/tips/ST04-014) for more information on social engineering attacks.
CISA also provides a section for [control systems security recommended
practices](https://www.us-cert.gov/ics/recommended-practices) on the ICS
webpage on [us-cert.gov](https://www.us-cert.gov/ics). Several recommended
practices are available for reading and download, including [Improving
Industrial Control Systems Cybersecurity with Defense-in-Depth
Strategies](https://www.us-
cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS webpage on us-cert.gov](https://www.us-cert.gov/ics) in
the Technical Information Paper, [ICS-TIP-12-146-01B--Targeted Cyber Intrusion
Detection and Mitigation Strategies](https://www.us-cert.gov/ics/tips/ICS-
TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to CISA for tracking
and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.