# ICS Advisory (ICSA-18-144-01)
## Schneider Electric Floating License Manager
Original release date: May 24, 2018
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-144-01)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-144-01)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-144-01)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 9.8**
* **ATTENTION** : Remotely exploitable/low skill level to exploit
* **Vendor** : Schneider Electric
* **Equipment** : Floating License Manager
* **Vulnerabilities** : Heap-based Buffer Overflow, Improper Restriction of Operations within the Bounds of a Memory Buffer, Open Redirect
## 2\. RISK EVALUATION
Successful exploitation of these vulnerabilities could cause a denial of
service, allow arbitrary execution of code with system level privileges, or
send users to arbitrary websites.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
The following products use the vulnerable Schneider Electric Floating License
Manager, a license management platform:
* SCADA Expert Vijeo Citect / CitectSCADA Version 7.30, 7.40,
* CitectSCADA Version 2015, 2016,
* Vijeo Historian/CitectHistorian Version 4.40, 4.50,
* CitectHistorian Version 2016,
* Citect Anywhere,
* PlantStruxure PES V4.3 SP1 and prior, and
* EcoStruxure Modicon Builder V3.0 and prior.
The following products are only affected by CVE-2016-10395:
* EcoStruxure Power Monitoring Expert 8.2 (Standard, DC, HC Editions),
* StruxureWare Power Monitoring Expert 8.1 (Standard, DC, HC Editions),
* StruxureWare Power Monitoring Expert 8.0 (Standard, DC, HC, Buildings Editions),
* StruxureWare Power Monitoring Expert 7.2.x,
* Energy Expert 1.x (formerly Power Manager), and
* EcoStruxure Power SCADA Operations 8.x (formerly PowerSCADA Expert) (Only with Advanced Reports and Dashboards Module).
### 3.2 VULNERABILITY OVERVIEW
### 3.2.1 [HEAP-BASED BUFFER OVERFLOW
CWE-122](https://cwe.mitre.org/data/definitions/122.html)
OpenSSL incorrectly uses pointer arithmetic for heap-buffer boundary checks,
which may allow denial of service attacks or other unspecified behavior.
[CVE-2016-2177](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-2177)
has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H)).
### 3.2.2 [IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY
BUFFER CWE-119](https://cwe.mitre.org/data/definitions/119.html)
This vulnerability can be exploited to cause an out-of-bounds memory read
access, which may allow remote code execution with system privileges.
[CVE-2016-10395](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-10395)
has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been
calculated; the CVSS vector string is
([AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H)).
### 3.2.3 [URL REDIRECTION TO UNTRUSTED SITE ('OPEN REDIRECT')
CWE-601](https://cwe.mitre.org/data/definitions/601.html)
An open redirect vulnerability has been identified, which may allow remote
attackers to redirect users to arbitrary websites for phishing attacks.
[CVE-2017-5571](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-5571)
has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been
calculated; the CVSS vector string is
([AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N)).
### 3.3 BACKGROUND
* **Critical Infrastructure Sectors:** Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems
* **Countries/Areas Deployed:** Worldwide
* **Company Headquarters Location:** France
### 3.4 RESEARCHER
Schneider Electric reported these vulnerabilities to NCCIC.
## 4\. MITIGATIONS
Schneider Electric recommends that users of affected Citect and PlantStruxure
products download and install the new version of the software located at:
<https://www.citect.schneider-
electric.com/documents/downloads/Floating_License_Manager_v2.1.0.0.zip>
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and
use the new version (V3.1) located at:
<https://partner.schneider-electric.com/partners/Menu/MyPartnership> (login
required)
StructureWare 7.2.x users should upgrade to Version 7.2.2 and apply the
floating licensing manager (FLM) patch from the following location:
<https://schneider-electric.box.com/s/n2fh1ym594pqvl87kf0zjsigamuryrje>
EcoStruxure/StruxureWare Power Monitoring Expert and Power SCADA Operations
users need to upgrade to Version 8.2. Energy Expert users need to upgrade to
Version 1.3. Once these are upgraded apply the Cumulative Update (CU) 2
located at:
<https://schneider-electric.box.com/s/kkdikodcksjj1dznqy68ko0j28wct7vb>
Schneider Electric has also released security notifications which contain
further details and upgrade instructions at the following links:
<https://www.citect.schneider-electric.com/safety-and-security-
central/36-security-notifications/9134-vulnerabilities-within-schneider-
electric-floating-license-manager>
<https://www.schneider-electric.com/en/download/document/SEVD-2018-137-01/>
<https://www.schneider-electric.com/en/download/document/SEVD-2018-144-01/>
<https://www.schneider-electric.com/en/download/document/SEVD-2018-046-01/>
NCCIC recommends users take defensive measures to minimize the risk of
exploitation of these vulnerabilities. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
NCCIC reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
NCCIC also provides a section for [control systems security recommended
practices](/ics/content/recommended-practices) on the ICS-CERT web page.
Several recommended practices are available for reading and download,
including[ Improving Industrial Control Systems Cybersecurity with Defense-in-
Depth Strategies](/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS-CERT website](/ics/) in the Technical Information Paper,
[ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation
Strategies](/ics/tips/ICS-TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to NCCIC for
tracking and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.
暂无评论