# ICS Advisory (ICSA-18-130-02)
## Rockwell Automation Arena
Original release date: May 10, 2018
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-130-02)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-130-02)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-130-02)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 5.5**
* **Vendor** : Rockwell Automation
* **Equipment** : Arena
* **Vulnerability** : Use After Free
## 2\. RISK EVALUATION
Successful exploitation of this vulnerability could cause the software
application to crash.
## 3\. TECHNICAL DETAILS
### 3.1 AFFECTED PRODUCTS
The following versions of Arena, simulation software for manufacturing, are
affected:
* Arena versions 15.10.00 and prior.
### 3.2 VULNERABILITY OVERVIEW
### 3.2.1 [USE AFTER FREE
CWE-416](https://cwe.mitre.org/data/definitions/416.html)
A use after free vulnerability caused by processing specially crafted Arena
Simulation Software files may cause the software application to crash,
potentially losing any unsaved data.
[CVE-2018-8843](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-8843)
has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been
calculated; the CVSS vector string is
([AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H)).
### 3.3 BACKGROUND
* **Critical Infrastructure Sectors:** Critical Manufacturing
* **Countries/Areas Deployed:** Worldwide
* **Company Headquarters Location:** Wisconsin, USA
### 3.4 RESEARCHER
Ariele Caltabiano, working with Trend Micro's Zero Day Initiative, reported
this vulnerability to NCCIC.
## 4\. MITIGATIONS
Rockwell Automation encourages affected users to upgrade to the latest version
of Arena software, v15.10.01 or later, which can be obtained from (login
required):
<https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1073588>
NCCIC recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
NCCIC reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
NCCIC also provides a section for [control systems security recommended
practices](/ics/content/recommended-practices) on the ICS-CERT web page.
Several recommended practices are available for reading and download,
including[ Improving Industrial Control Systems Cybersecurity with Defense-in-
Depth Strategies](/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS-CERT website](/ics/) in the Technical Information Paper,
[ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation
Strategies](/ics/tips/ICS-TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to NCCIC for
tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability. This
vulnerability is not exploitable remotely. High skill level is needed to
exploit.