# ICS Advisory (ICSA-18-128-02)
## Siemens Siveillance VMS (Update A)
Original release date: May 08, 2018 | Last revised: May 24, 2018
[Print Document](javascript:window.print\(\);)
[Tweet](https://twitter.com/share?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-128-02)
[Like Me](https://www.facebook.com/sharer.php?u=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-128-02)
[Share](http://www.addthis.com/bookmark.php?url=https%3A%2F%2Fus-
cert.cisa.gov%2Fics%2Fadvisories%2FICSA-18-128-02)
### Legal Notice
All information products included in [https://us-cert.gov/ics](/ics) are
provided "as is" for informational purposes only. The Department of Homeland
Security (DHS) does not provide any warranties of any kind regarding any
information contained within. DHS does not endorse any commercial product or
service, referenced in this product or otherwise. Further dissemination of
this product is governed by the Traffic Light Protocol (TLP) marking in the
header. For more information about TLP, see [https://www.us-
cert.gov/tlp/](/tlp/).
* * *
## 1\. EXECUTIVE SUMMARY
* **CVSS v3 8.1**
* **ATTENTION** : Exploitable remotely
* **Vendor** : Siemens
* **Equipment** : Siveillance Video Management Software (VMS)
* **Vulnerability** : Deserialization of Untrusted Data
## 2\. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled
ICSA-18-128-02 Siemens Siveillance VMS that was published May 8, 2018, on the
NCCIC/ICS-CERT website.
## 3\. RISK EVALUATION
Successful exploitation of this vulnerability by the affected ports in .NET
Remoting deserialization could allow elevation of privileges and/or cause a
denial-of-service.
## 4\. TECHNICAL DETAILS
### 4.1 AFFECTED PRODUCTS
The following versions of Siveillance VMS, an IP video management software,
are affected:
* Siveillance VMS 2016 R1, all versions prior to V10.0a,
* Siveillance VMS 2016 R2, all versions prior to V10.1a,
* Siveillance VMS 2016 R3, all versions prior to V10.2b,
* Siveillance VMS 2017 R1, all versions prior to V11.1a,
* Siveillance VMS 2017 R2, all versions prior to V11.2a, and
* Siveillance VMS 2018 R1, all versions prior to V12.1a.
### 4.2 VULNERABILITY OVERVIEW
### 4.2.1 [DESERIALIZATION OF UNTRUSTED DATA
CWE-502](https://cwe.mitre.org/data/definitions/502.html)
The Recording Server, Management Server, and Management Client on Ports
6473/TCP local connection only, 7474/TCP, 8966/TCP local connection only, and
Port 9993/TCP use an exploitable .NET Framework Remoting deserialization
level.
An attacker could exploit this vulnerability by accessing the vulnerable
ports, allowing elevation of privileges or causing a denial-of-service;
compromising confidentiality, integrity, and availability of the targeted
system.
[CVE-2018-7891](http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7891)
has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been
calculated; the CVSS vector string is
([AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H](https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H)).
### 4.3 BACKGROUND
* **Critical Infrastructure Sectors:** Unknown
* **Countries/Areas Deployed:** Worldwide
* **Company Headquarters Location:** Germany
### 4.4 RESEARCHER
Siemens ProductCERT reported this vulnerability to NCCIC.
## 5\. MITIGATIONS
Siemens has released updates for several affected products and recommends
users update to the new version.
**\--------- Begin Update A Part 1 of 1 --------**
* Siveillance VMS 2016 R1: Update to V10.0a (Obtain the update via the local Siemens representative)
* Siveillance VMS 2016 R2: Update to V10.1a (Obtain the update via the local Siemens representative)
* Siveillance VMS 2016 R3: Update to V10.2b (Obtain the update via the local Siemens representative)
* Siveillance VMS 2017 R1: Update to V11.1a (Obtain the update via the local Siemens representative)
* Siveillance VMS 2017 R2: Update to V11.2a (Obtain the update via the local Siemens representative)
* Siveillance VMS 2018 R1: Update to V12.1a (Obtain the update via the local Siemens representative)
Contact Siveillance Technical Support at:
[siveillance.support.industry@siemens.com](mailto:siveillance.support.industry@siemens.com)
**\--------- End Update A Part 1 of 1 ----------**
As a general security measure, Siemens strongly recommends protecting network
access to devices with appropriate mechanisms. In order to run the devices in
a protected IT environment, Siemens specifically recommends users configure
the environment according to Siemens' [Operational Guidelines for Industrial
Security](https://www.siemens.com/content/dam/webassetpool/mam/tag-siemens-
com/smdb/digital-factory/industrial-
security/online/documents/whitepapers/en/operational-guidelines-industrial-
security-en.pdf) and follow the recommendations in the product manuals.
Additional information on industrial security by Siemens can be found at:
<https://www.siemens.com/industrialsecurity>
For more information on this vulnerability and associated software updates,
please see Siemens security advisory SSA-457058 on their website:
<https://www.siemens.com/cert/advisories>:
NCCIC recommends users take defensive measures to minimize the risk of
exploitation of this vulnerability. Specifically, users should:
* Minimize network exposure for all control system devices and/or systems, and ensure that they are [not accessible from the Internet](/ics/alerts/ICS-ALERT-10-301-01).
* Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
NCCIC reminds organizations to perform proper impact analysis and risk
assessment prior to deploying defensive measures.
NCCIC also provides a section for [control systems security recommended
practices](/ics/content/recommended-practices) on the ICS-CERT web page.
Several recommended practices are available for reading and download,
including[ Improving Industrial Control Systems Cybersecurity with Defense-in-
Depth Strategies](/sites/default/files/recommended_practices/NCCIC_ICS-
CERT_Defense_in_Depth_2016_S508C.pdf).
Additional mitigation guidance and recommended practices are publicly
available on the [ICS-CERT website](/ics/) in the Technical Information Paper,
[ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation
Strategies](/ics/tips/ICS-TIP-12-146-01B).
Organizations observing any suspected malicious activity should follow their
established internal procedures and report their findings to NCCIC for
tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability. High skill
level is needed to exploit.